Thermo Scientific Orion Star A329 pH/ISE/Conductivity/RDO/Dissolved Oxygen Portable Multiparameter Meter Kit

Part Number: STARA3295

List Price

$2,940.00

Discount

-$312.00 (10.6%)  

Freight

Always Free!

Total Price   

$2,628.00

Quantity  

Normally Ships in 4-10 Business Days

Condition

New, Manufacturer Direct-Ship  What's This?

Part Number

STARA3295

Warranty

3 year meter replacement warranty

AC Adapter

Universal 50-60 Hz, 100-240 VAC power adapter (sold separately, Cat. No. 1010003)

Accuracy Barometer

6 mmHg

Accuracy Conductivity

0.5% of reading 1 digit > 3 ?S; 0.5% of reading 0.01 ?S ? 3 ?S

Accuracy ISE

0.2 mV or 0.05% of reading whichever is greater

Accuracy mV

0.2 mV or 0.05% of reading whichever is greater

Accuracy Percent Saturation (Polarographic DO)

2 % saturation or 2% of reading whichever is greater

Accuracy Percent Saturation (RDO)

2 % saturation ? 200 % saturation, 10 % saturation > 200 % saturation

Accuracy pH

0.002pH

Accuracy Polarographic DO

0.2 mg/L or 2% of reading, whichever is greater

Accuracy RDO

0.1 mg/L up to 8 mg/L, 0.2 mg/L from 8 to 20 mg/L, 10% of reading up to 50 mg/L

Accuracy Resistivity

0.5% of reading 1 digit

Accuracy Salinity

0.5% of reading 1 digit

Accuracy TDS

0.5% of reading 1 digit

Accuracy Temperature

0.1C

Advanced ISE Functions

Segmented (point-to-point) slope, non-linear selectable auto-blank, low concentration range stability

Alarm Output

High/low limit alarm, calibration due alarm

Backlight

Yes, selectable

Barometric Pressure Correction

400 to 850 mmHg, automatic using built-in barometer or manual entry

Battery Life (Average)

800 hours

Battery Type

Four AA (included)

Calibration Modes

pH with calibration editing option, ion concentration (ISE) with calibration editing option, relative mV (RmV), ORP, conductivity with calibration editing option, dissolved oxygen and temperature

Calibration Modes

Water-saturated air, air-saturated water, manual (Winkler titration), zero point

Calibration Points Conductivity

Up to 5

Calibration Points ISE

1 to 5

Calibration Points mV

1 point relative mV (RmV) mode, 1 point ORP mode

Calibration Points pH

1 to 5

Cell Constant

0.001 to 199.9 cm-1

Certifications Compliance

CE, TUV 3-1, FCC Class A

Channels

3

Data Log Function Type

Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous measure mode

Data Management Details

Transfer single, range or all data points to printer or computer

Data Points

5000 with date and time stamp

Description

Orion Star A329 pH/ISE/conductivity/RDO/DO portable meter kit with ROSS Ultra Triode gel pH/ATC electrode, conductivity sensor, RDO optical DO sensor, solutions, meter armor and field case

Dimensions LxWxH

24 cm x 10 cm x 6.5 cm (9.5'' x 3.9'' x 2.6'')

Display Type

Graphic LCD with backlight

Includes

Star A329 pH/ISE/conductivity/RDO/DO meter, 8107UWMMD ROSS Ultra Triode gel-filled epoxy-body pH/ATC electrode with 3 meter cable, 013010MD Orion DuraProbe 4-cell (K=0.475) conductivity sensor with 3 meter cable, 087010MD Orion RDO optical dissolved oxygen sensor with 3 meter cable, 910410-WA Orion pH 4.01 buffer pouch 10 pack, 910710 Orion pH 7.00 buffer pouch 10 pack, 911010 Orion pH 10.01 buffer pouch 10 pack, 911110 Orion rinse solution pouch 10 pack, 810001 ROSS storage solution, 01100710 Orion 1413 S conductivity standard pouch 10 pack, RDO calibration sleeve, RDO stainless steel sensor guard, protective meter armor, hard-sided field case, 4 AA batteries, literature, computer cable and calibration test certificate

Inputs

BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (conductivity sensor with built-in temperature or ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature)

IP Rating

IP-67

Isopotential Point

7.000pH

Keypad

Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys

Languages

English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update

Measurement Modes

pH, mV, relative mV (RmV) or ORP with temperature; conductivity, TDS, salinity or resistivity with temperature; dissolved oxygen as % saturation or mg/L with temperature and barometric pressure

Memory

Non-volatile memory preserves data log, calibration log and meter settings

Methods

10 per channel with password protection

Model

Orion Star A329 pH/ISE/mV/RmV/ORP/Conductivity/TDS/Salinity/Resistivity/RDO Optical/Dissolved Oxygen/Temperature Portable Meter

Outputs

USB, RS232

Power Supply

4 AA batteries (included) or universal AC adapter (sold separately)

Range Barometric Pressure

400 to 850 mmHg

Range Conductivity

0.001 S/cm to 3000 mS/cm

Range ISE

0.0001 to 19900 with selectable units of ppm, Molar, mg/L, %, ppb or none

Range mV

2000.0mV

Range ORP

2000.0mV

Range Percent Saturation (Polarographic DO)

0.0 to 600.0 % saturation

Range Percent Saturation (RDO)

0.0 to 500.0 % saturation

Range pH

-2.000 to 20.000pH

Range Polarographic DO

0.00 to 90.00 mg/L

Range RDO

0.00 to 50.00 mg/L

Range Relative mV

2000.0mV

Range Resistivity

2 ohm to 100.0 meg-ohm

Range Salinity

0.06 to 80.00 psu, 0.05 to 42.00 ppt

Range TDS

0.001 to 200.0 ppm

Range Temperature

-5.0 to 105.0 C, 22.0 to 221.0 F

Relative Humidity Range

5 to 85 %, non-condensing

Resolution Barometric Pressure

1 mmHg

Resolution Conductivity

0.001 ?S minimum, auto ranging up to 4 significant digits

Resolution ISE

0.0001 minimum, 1 to 3 significant digits (user selectable)

Resolution mV

0.1mV

Resolution Percent Saturation (Polarographic DO)

0.1, 1 % saturation

Resolution Percent Saturation (RDO)

0.1, 1 % saturation

Resolution pH

0.1, 0.01, 0.001pH

Resolution Polarographic DO

0.01, 0.1 mg/L

Resolution RDO

0.01, 0.1 mg/L

Resolution Resistivity

1 ohm or 0.1 meg-ohm, auto ranging

Resolution Salinity

0.01 psu or 0.01 ppt minimum, auto ranging

Resolution TDS

0.001 ppm minimum, auto ranging up to 4 significant digits

Resolution Temperature

0.1C, 0.1F

Salinity Correction Factor

0.0 to 45.0 ppt, automatic correction using conductivity reading or manual entry of sample salinity

Salinity Measurement Modes

Practical salinity (psu) or natural sea water (ppt)

Stability

Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting

TDS Factor Range

Linear (0.02 to 9.99)

Temperature Ambient Operating

5 to 45C, 41 to 113F

Temperature Compensation

Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off with warning) or off

Temperature Probe Calibration

1 point temperature offset calibration

Temperature Reference Options

5, 10, 15, 20, 25C

Temperature Selection

Manual or automatic with ATC temperature probe

Warranty

3 year meter warranty

Weight

0.5 kg, 1.2 lbs

Included with Purchase

Orion Star A329 pH/ISE/Conductivity/RDO/Dissolved Oxygen Portable Meter

8107UWMMD Orion ROSS Triode 3-in-1 pH/ATC probe, 3m cable

013010MD Orion DuraProbe conductivity cell, 3m cable

087010MD Orion RDO optical/luminescence-based probe with 3m cable, stainless steel guard, calibration sleeve and optical/luminescence-based cap

910410 Orion pH 4.01 buffer, 10 pouches

910710 Orion pH 7.00 buffer, 10 pouches

911010 Orion pH 10.01 buffer, 10 pouches

810001 Orion ROSS electrode storage solution, 475 mL

01100710 Orion 1413 μS conductivity standard, 10 pouches

911110 rinse solution, 10 pouches

Protective armor with probe holders

Hard carrying case

Four AA batteries (installed)

Star A329 Models with Other Options

STARA3290

Includes

Orion Star A329 pH/ISE/Conductivity/RDO/Dissolved Oxygen Portable Meter

Four AA batteries (installed)

$1,460.00

STARA3290 Full Specs and Ordering Information

 

About Us - Contact Us - Our Products - Terms of Service - Privacy Policy

McQueen Labs Accepts All Major Credit Cards

All images and information on this web site are Copyright © 2002-2016 McQueen Laboratory Supply Company.
All information current as of Monday, June 27, 2016