Thermo Scientific Lindberg/Blue M 55.3L D2 OTC LGO Box Furnace

Part Number: BF51842PBC-1

Model BF51842PBC-1, Thermo Scientific Lindberg/Blue M 55.3L D2 OTC LGO Box Furnace

Sample Photo May
Show Optional Parts
Click to Enlarge

List Price

$11,284.00

Discount

-$2,389.00 (21.2%)

Freight

Always Free!

Total Price   

$8,895.00

  Please Explain!

Quantity  

Normally Ships: 2-3 Weeks

Condition

New, Manufacturer Direct-Ship  What's This?

Part Number  

BF51842PBC-1

Capacity

2 Cubic Feet, 55.3 Liters

Temperature Range

100° to 1200°C

Interior Dim

15"H x 15"W x 15"D

Exterior Dim

33"H x 29"W x 28"D

Weight

280 lbs

Power Output

5800 Watts

Electrical  

208-240V 50/60Hz

Warranty

1 Year Parts and Labor

Thermo Scientific LGO Series Box Furnaces feature the latest technical advances in heating elements, insulation and temperature control, all integrated into a self-contained cabinet.

Furnaces feature patented LGO (light gauge overbend) heating elements and Moldatherm insulation for efficient and economical transfer of heat to the chamber, with low exterior temperatures.

Features of the BF51842PBC-1 Laboratory Furnace

Includes the D2 Controller

Programmable with thirty (30) stored programs with 300 segments for use (maximum of 99 segments per program). Each segment includes one ramp and one dwell, so you can program up to 99 ramp/dwell cycles.

The ramp is used to vary the heat-up or cool-down rate to your specified setpoint. The furnace will then dwell (hold the temperature) at a set level for a specified time.

A large 5-digit LED display shows actual temperature and an LCD display provides trend recording function, graphic prompts, configurable display data, and custom messages set by the customer.

See bottom of page for more details on controllers.

Microprocessor Control

Selectable self-tuning PID control (proportional, integral, derivative) provides optimum thermal process and prevents overshoot

Control panel designed for easy access and maintenance

Main power ON/OFF switch on control panel

Adjustable high-limit overtemperature protection

Can be configured to display temperature in either °C or °F

Over Temperature Control (OTC)

Adjustable digital overtemperature control

Protects furnace and load in the event of primary control circuit failure

Overrides main controller and shuts off power to furnace if high limit is reached

Manual reset required for safety

Operates via magnetic contacts through signal from independent thermocouple

High Quality Features and Construction

Variable heat-up rate eliminates thermal shock to materials with quick heat-up and cool-down rates

Side-hinge door for convenient operation and full chamber access

Air vent (1in. dia., top) and air inlet (1/4" Male Pipe Thread, rear) for inert atmosphere exchange; will experience some leakage at door

Self-tuning, digital instrumentation for precise temperature setpoint and display

Platinel II thermocouple for long-term stability

Safety door switch to interrupt power to heating element when door is opened; protects heating element and minimizes exposure to end-user

Three shelf positions; 1 two-part shelf included with furnace

Moldatherm hearthplate supports load and prevents damage due to spillage

NOTE: Requires customer-supplied power cord or hardwiring

(PDF Download) Lindberg LGO Lab Box Furnace Brochure

About the Controllers B2, C2, and D2

This furnace is available with three different controllers allowing various levels of control and programs. All of the controllers are digital. The BF51842PBC-1 has the D2 controller.

B2 Controller
Single setpoint with one ramp to setpoint. The ramp is used to vary the heat-up rate to your specified setpoint. The furnace will then hold the temperature at a set level. An LED display simultaneously shows both setpoint and actual furnace temperatures.
View B2-Controlled Unit, BF51841C
View B2-Controlled Unit, BF51841BC, with Over Temperature Control

C2 Control Panel

C2 Controller
Programmable with one (1) stored program of sixteen (16) segments. Each segment includes one ramp and one dwell, so you can program 16 ramp/dwell cycles. The ramp is used to vary the heat-up rate to your specified setpoint. The furnace will then dwell (hold the temperature) at a set level for a specified time. An LED display simultaneously shows both setpoint and actual furnace temperatures. Accuracy of controller: ±0.3%.

View C2-Controlled Unit, BF51842C
View C2-Controlled Unit, BF51842BC, with Over Temperature Control

 

D2 Control Panel

D2 Controller
Programmable with thirty (30) stored programs with 300 segments for use (maximum of 99 segments per program). Each segment includes one ramp and one dwell, so you can program up to 99 ramp/dwell cycles. The ramp is used to vary the heat-up or cool-down rate to your specified setpoint. The furnace will then dwell (hold the temperature) at a set level for a specified time. Program patterns can be based on either time or rate. A large 5-digit LED display shows actual temperature and an LCD display provides trend recording function, graphic prompts, configurable display data, and custom messages set by the customer. Accuracy of controller: ±0.1%.

You are viewing the D2-Controlled Unit with Over Temperature Control
View D2-Controlled Unit, BF51842PC, w/out Over Temperature Control
View D2-Controlled Unit, BF51842PFMC, with Flowmeter
View D2-Controlled Unit, BF51842PBFMC, with Flowmeter and Over Temperature Control

 

Optional Accessories

Replacement Shelf for BF51842PBC-1

Part Number: 7221-2067-001

This is a replacement shelf for the BF51842PBC-1 Lindberg furnace.

List Price: $163.56

Sale Price: $163.00

Free Shipping

Quantity  







Share Item

Share on Facebook    Share on Twitter    Share on Google+

Lab Equipment Freezers Refrigerators Hot Plates Stirrers Water Baths Furnaces Ovens Liquid Nitrogen Storage Water Filters Owl Electrophoresis Incubators Shakers Centrifuges Nalgene Bottles

 

About Us - Contact Us - Our Products - Terms of Service - Privacy Policy

SecurityMetrics for PCI Compliance, QSA, IDS, Penetration Testing, Forensics, and Vulnerability Assessment     McQueen Labs is an Upfront Merchant on TheFind. Click for info.     Valid XHTML 1.0 Strict    

McQueen Labs Accepts All Major Credit Cards

All images and information on this web site are Copyright © 2002-2014 McQueen Laboratory Supply Company.
All information current as of Thursday, October 2, 2014